 Voltage Transducer AV100 Series
For the electronic measurement of voltages : DC, AC, pulsed..., with a galvanic isolation between the primary circuit (high voltage) and the secondary circuit (electronic circuit).
VPN = 50...1500 V
Electrical data
Primary nominal R.m.s or DC voltage Primary Voltage R.m.s. voltage for AC Type 1) measuring range isolation test (50 Hz/1min) VPN (V) VPmax (V) Vd (kV) 50 75 3.3 AV 100-50 125 187.5 3.3 AV 100-125 150 225 3.3 AV 100-150 250 375 3.3 AV 100-250 500 750 3.3 AV 100-500 750 1125 4.3 AV 100-750 1000 1500 5.5 AV 100-1000 1500 2250 6.5 AV 100-1500 Not measurable overload 2 x VPmax (1s/h) VDC Measuring resistance RM min RM max @ VC=11.4V 0 47 @ VC=22.8V 0 184 Secondary nominal r.m.s. current 50 mA Supply voltage ( 5 %) DC 12 .. 24 V Current consumption 50+IS mA Max Common mode voltage U HT+ + U HT- 4.2 k VDC and UHT+ - U HT- VPMAX R.m.s. voltage for partial discharge 1.1 2) kV extinction @ 10pC 2.2 3) kV
Features
* Insulated plastic case recognized
according to UL 94-V0.
* Included primary resistor
Advantages
* * * * * * *
Low power Excellent accuracy Very good linearity Low thermal drift Low response time High bandwidth High immunity to external interference * Low disturbance in common mode.
VP RM
ISN VC Ic
Ve
Applications
* AC variable speed drives and servo
motor drives
Accuracy - Dynamic performance data
XG XG XG Overall Accuracy @ VPN , TA = + 25C Overall Accuracy @ VPN , TA = - 25 .. + 70C Overall Accuracy @ VPN , TA = - 40 .. + 85C Linearity @ TA = 25C Offset current @ VP = 0, TA = 25C Response time @ 10 % of VPmax Frequency bandwidth (- 3 dB) 0.7 % 1.5 % 1.7 % < 0.1 % 0.15 mA Between 10 and 13 s DC .. 13 kHz
L
IO tr f
* Static converters for DC motor drives * Battery supplied applications * Uninterruptible Power Supplies
(UPS)
* Power supplies for welding
applications .
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards - 40 .. + 85 - 50 .. + 90 375 EN 50155 EN 50124-1 NFF16101/2 C C g
Notes : 1) Between primary and secondary 2) For models AV 100-50 to 750 3) For models AV 100-1000 & AV 100-1500 030523/4
LEM Components
Dimensions AV100 Series (in mm. 1 mm = 0.0394 inch)
Front view Left view
HT+
HT+ M -
Secondary terminals
Terminal + : Supply voltage +12 .. 24 V Terminal M : Measure Terminal - : Supply voltage - 12 .. 24V
Connection
AV100 AV100
TOP view Mechanical characteristics
* General tolerance * Fastening
1 mm 2 holes 6.5 mm Distance between holes axes : 124mm * Fastening & connection of primary 2 x M5 * Fastening & connection of secondary 3 x M5 or 3 Faston 6.35 x 0.8mm Output connections must be made with screened cables * Fastening torque: 2.2 Nm
Remarks
* IS is positive when VP is applied on terminal +HT. * This is a standard model. For different versions, please
contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.


▲Up To Search▲   

 
Price & Availability of AV100-500

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X